- 8 -
D. Button function
Field lights up, battery over charge voltage can be set.
when the battery is over charge, the field flashes.
Field lights up, battery over charge recovery voltage
can be set.
Field lights up, battery floating charge voltage can be
set. The field flashes during floating charge.
Field lights up, battery booster charge voltage can be
set. The field flashes during booster charge (improving
charge).
Field lights up, battery equalizing charge voltage can be
set. The field flashes during equalizing charge.
Field lights up, Time control 1 can be set (the first light
working- time). When set as 0, the controller is for
household use.
Field lights up, choosing street light mode, the time
control 2 can be set. (light off- time)
Field lights up, choosing street light mode, the time
control 3 can be set. (the second light working-time)
Field lights up, when 1 occurs at the first place of the
display area, light control OPEN voltage (when lights
on) can be set. When finished, 2 occurs at the first place
of the display area, light control CLOSE voltage (when
lights off) can be set.
The field flashes during MPPT charge.
When alarms, field lights up