1 Air Filter
2 Air circulating fan
3 Heat exchanger access cover
4 Data plate
5 Time control
6 Multifunctional control
7 Fan Delay Control/Limit Switch
8 Pilot burner
9 Burner Assembly
10 Gas connection
11 Heat shield
12 Piezo igniter unit
13 Spillage monitoring Device (TTB)
(Air heater)
14 Spillage monitoring Device (TTB)
(Water Heater)
These appliances have been tested and certified by B G Technology for use with PROPANE gas G31.
Note: If a HIJAN 6P circulator is fitted, the relevant Installation, Commissioning and Servicing instructions provided with that
appliance must also be observed.
1. BRIEF DESCRIPTION
HI-SPEC J32P and HI-SPEC J32RP
WARM AIR HEATERS
with Conventional Control
INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS
G.C. No 42 451 07 HI-SPEC J32P
G.C. No 42 451 08 HI-SPEC J32RP
Publication No. ZZ 982/7
February 2007
These instructions are to be left with the User or adjacent to the Gas Meter
1
Fig. 1
1.1 HI-SPEC J32P is an open-flued, fan assisted downflow, ducted warm air heater, supplied with conventional control. A
HIJAN 6P circulator is available as an option. HI-SPEC J32RP, which has an integral rear rising duct is also available as
an option. A Spillage Monitoring Device (TTB) is fitted which senses the temperature in the draught diverter, and shuts
down the appliance when this temperature rises due to the presence of flue gases.
1.2 The Air heater output is 8.30kW (29.88MJ/h, 28,320Btu/h) . “Summer air circulation” of unheated air is available by
manual selection (see User’s Instructions). HIJAN 6P output is 3.56kW (12.8MJ/h, 12,150Btu/h).
THIS APPLIANCE CONFORMS TO BS EN 55014
3
6
5
9
10
11
8
13
Johnson and Starley prides itself on its ability to supply spare parts quickly and efficiently. If you have a problem in obtaining a
spare part, please contact Johnson and Starley Spares Department at the address below.
JOHNSON & STARLEY LTD.
Telephone: (01604) 762881 Rhosili Road,
Brackmills,
Fax: (01604) 767408 Northampton NN4 7LZ
14
7
12
4
1
2
10. SHORT LIST OF SPARES
HI-SPEC J32P and HI-SPEC J32RP
KEY G.C No MFR’S No DESCRIPTION QTY
1 245 501 1000-0500370 Fan Assembly 1
2 H26-712 1000-0709640 Multifunctional Control 1
Honeywell V8600C 1129
BOS 02397/2 Pilot Burner 1
1000-0701440 Pilot Injector (No 19) 1
1000-0704730 Pilot Feed Pipe 1
390 210 BOS 01970 Igniter Electrode 1
BOS 02394 Igniter Lead 1
381 626 1000-0704830 Thermocouple 1
4 378 466 BOS 02031 Time Control 1
5 1000-0708020 Burner Bar Assembly 1
6 1000-0708040 Main Injector ( Bray 1.78mm ) 1
7 395 945 1000-0700570 Piezo Unit (High Energy) 1
8 245 509 1000-0513820 Fuse T3.15A anti-surge 1
13 386 634 1000-0503730 Spillage Monitor Device (TTB) 1
14 J304-0511000 Electrical Panel 1
15 245 520 1000-0516125 Fan Delay/Limit Control 1
16 1000-0515190 Transformer Fan Speed 1
17 245 525 1000-0515730 Transformer 24 volt 1
18 245 413 1000-0511760 Relay Module 1
19 J304-0769000 TTB Assembly (water heater) 1