Fireplace
10 kW and 14 kW
INSTALLATION, USE AND
MAINTENANCE MANUAL
To be kept by the purchaser
Pellet operated air heating fireplace
JOLLY SYNTHESIS 68-80 JOLLY STAR 68-80

Table of Contents

Questions and Answers

  • D
    donaldsmithSep 12, 2025
    How to turn on the Emergency Console on Jolly Mec JOLLY SYNTHESIS 68-80 Indoor Fireplace?
    • J
      jthorntonSep 12, 2025
      If the Emergency Console of your Jolly Mec Indoor Fireplace is not on, check that the fireplace plug is securely inserted in the mains socket and the socket at the back of the fireplace. Also, check that the FLAT cable is connected to the electronic circuit board correctly, and that the protection fuses are working efficiently, including those connected to the electronic circuit board and those in the fireplace socket.
  • M
    Mary PerkinsAug 22, 2025
    What to do if my Jolly Mec JOLLY SYNTHESIS 68-80 displays AL05 power failure?
    • W
      William BarrettAug 22, 2025
      If your Jolly Mec Indoor Fireplace is showing the error 'AL05|power failure', it means the THRESHOL MINIMUM setting wasn't reached during start-up. Try these steps: Check the electrical element's condition, make sure the element guide tube is clean, ensure the firebox is perfectly clean before starting, verify the pellet preloading quality, and confirm that the pellet load and fumes extractor fan speed settings are correct.
  • D
    Dana ChanAug 25, 2025
    What does AL03 fume hot mean on my Jolly Mec JOLLY SYNTHESIS 68-80 Indoor Fireplace?
    • A
      Anna FloresAug 25, 2025
      If your Jolly Mec Indoor Fireplace is showing the error 'AL03|fume hot', it means the fumes temperature is too high. Check the position of the fumes probe. Also, check if the air exchange fan is working correctly, if the stove is dirty (and clean it, if necessary), and if the pellet load settings are correct.
  • C
    Colleen SimpsonAug 26, 2025
    What does AL06 empty pellet mean on my Jolly Mec Indoor Fireplace?
    • J
      Judy GuzmanAug 26, 2025
      If your Jolly Mec Indoor Fireplace displays the error 'AL06|empty pellet', it means the temperature fell below the THRESHOL LAVORO setting while the stove was running. Ensure there are enough pellets in the hopper, check that the pellet load times are set correctly, and verify the THRESHOL LAVORO setting.
  • C
    colemantaylorAug 27, 2025
    What does AL04 vacuum failure mean for Jolly Mec JOLLY SYNTHESIS 68-80 Indoor Fireplace?
    • R
      Rachel RossAug 27, 2025
      If your Jolly Mec Indoor Fireplace displays the error 'AL04|vacuum failure', it indicates that the control unit isn't detecting the correct fumes extractor RPM. Make sure all electrical connections are secure. Also, check if the combustion fan is very dirty and if any foreign objects are caught in the fan or external motor.
  • Z
    zsantiagoAug 29, 2025
    What to do if my Jolly Mec JOLLY SYNTHESIS 68-80 Indoor Fireplace displays AL07 thermal safety?
    • N
      nsmithAug 29, 2025
      If your Jolly Mec Indoor Fireplace displays the error 'AL07|thermal safety', it indicates that the thermal safety switch has tripped. To resolve this, check that the exchange fan is working properly, ensure the stove is clean, and verify the pellet load settings.
  • A
    Amy SmithSep 13, 2025
    Why does the exchange fan air smell of smoke in my Jolly Mec Indoor Fireplace?
    • R
      Rachel MccarthySep 13, 2025
      If the exchange fan air smells of smoke in your Jolly Mec Indoor Fireplace, check the exchange fan, as it might be dirty.
  • J
    Jessica BergSep 10, 2025
    Why doesn't my Jolly Mec Indoor Fireplace remote control work?
    • M
      Morgan HarmonSep 10, 2025
      If the remote control for your Jolly Mec Indoor Fireplace isn't working, first check that the batteries are not dead and are inserted correctly. Then, point the remote control at the emergency console. Also, make sure the fireplace is powered up and the display is working.
  • B
    bgreenSep 6, 2025
    Why aren't pellets dropping into my Jolly Mec JOLLY SYNTHESIS 68-80 Indoor Fireplace?
    • J
      jody55Sep 6, 2025
      If the pellets are not dropping into the firebox of your Jolly Mec Indoor Fireplace, it could be due to a few reasons. The pellets might have run out; if so, refill the container. The gear motor might not be running because it is not connected to the mains or is mechanically disconnected from the auger. The auger could also be blocked by a foreign body or very hard pellets. If the pellets are very hard, use the recommended pellet types.
  • R
    Rebecca GallowaySep 8, 2025
    Why is the flame very inconsistent in my Jolly Mec Indoor Fireplace?
    • Y
      Yolanda CarlsonSep 8, 2025
      If the flame in your Jolly Mec Indoor Fireplace is very inconsistent, check the bottom of the pellet container for large deposits of sawdust. Also, the gear motor may have broken gearings.

Jolly Mec JOLLY SYNTHESIS 68-80 Specifications

General IconGeneral
CategoryIndoor Fireplace
BrandJolly Mec
ModelJOLLY SYNTHESIS 68-80
Fuel TypeWood
Flue Diameter150 mm
Width80 cm