Doc.No.: 08400-006-DE
Page 9 of 19
.
3.6. PLUG-IN RELAY MODULE (BRD 99400-011)
A relay module for activation of external signal device can be installed in the betteryless
telephones: 4040 / 4050 / 4051 / 4060 / 4061
The relay module is to be mounted by the installer. The unit is delivered separately, and is to be
plugged into the appropriate telephone unit.
Open the backbox on the telephone unit.
Plug the relay unit into the receptacle on the PCB inside the telephone. Make sure the
connector pins make contact.
Snap the stand off`s (2pcs) into the holes in the PCB.
Make the connections according to the installation drawings 99400-017-EC or 99400-018-
EC.
If DC voltage is used, make sure the polarity is correct. (Indication on the dwgs. 99400-
017-EC and 99400-018-EC)
4. LIST OF FACILITIES
4.1. BATTERYLESS AMPLIFIERT UNIT, TYPE 4000
- Interface for up to 24 batteryless telephones
- Extreme low current drain speech amplifier.