Wood consumption
Jøtul F 100 has a nominal heat output of 5,0 kW. Use of
wood, with nominal heat emission: Approx. 1,8 kg/h. Another
important factor for proper fuel consumption is that the
logs are the correct size. The size of the logs should be:
Kindling:
Length: 20 - 40 cm
Diameter: 2 - 5 cm
Amount per fire: 6 - 8 pieces
Firewood (split logs):
Length: 40 cm
Diameter: Approx. 8 cm
Intervals for adding wood: Approx. every 60 minutes
Size of the fire: 1,8 kg
Amount per load: 2 pieces.
Nominal heat emission is achieved when the air vent is open
approximately 50%.
3.0 Installation
3.1 Floor
Foundations
It must be ensured that the foundations are dimensioned for
the fireplace. Cf. «2.0 Technical data» for specification of weight.
It is recommended that flooring which is not fastened to the
foundations – so-called floating flooring – is removed during
installation.
Requirements for protection of wooden
flooring
Jøtul F 100 has a heat shield underneath which protects the floor
from radiation. The product can therefore be placed directly on a
wooden floor that is covered by a metal plate or other suitable,
non-inflammable material. The recommended minimum
thickness is 0,9 mm.
Jøtul recommends that any flooring made of combustible
material, such as linoleum, carpets, etc. should be removed from
under the floor plate
Requirement for protecting combustible
flooring in front of fireplace
The front plate must be in accordance with national laws and
regulations.
Contact your local building authorities regarding restrictions and
installation requirements.
3.2 Walls
Distance from the wall of flammable
material – cf. fig. 1
The fireplace is authorised for use with an uninsulated flue with
the distances to the wall of flammable material as shown in fig 1.
Distance to the flammable wall protected by
a firewall
Firewall requirement
The firewall must be at least 100 mm thick and be made of brick,
concrete-stone or light concrete. Other materials and structures
with satisfactory documentation may also be used.
3.3 Ceiling
Jøtul F 100 may be assembled with the upper edge of the hot
air aperture min 1200 mm beneath the ceiling of the flammable
material