eNgliSh
Table of contents
1.0 Relationship to the authorities .............14
2.0 Technical data ........................................14
3.0 Safety precautions ................................. 15
4.0 Installation ............................................. 15
5.0 Use .......................................................... 17
6.0 Maintenance ..........................................18
7.0 Service .....................................................19
8.0 Optional equipment ..............................19
9.0 Reasons for operational problems -
troubleshooting .....................................19
Figures ...........................................................53
1.0 Relationship to the
authorities
Installation of a fireplace must be according to local codes and
regulations in each country.
All local regulations, including those that refer to national and
European standards, shall be complied with when installing the
product.
Instructions for mounting, installation and use are enclosed with
the product. Prior to using the product the installation must be
approved by a qualified person.
A product data plate in heat resistant material is located on the
heat shield under the product. This contains information about
identification and documentation for the product.
2.0 Technical data
Material: Cast iron
Finish: Black paint, blue black enamel
Fuel: Wood
Log length, max: 40 cm
Effect: 2,3 - 8,5 kW
Flue outlet: Top, rear
Flue pipe dimension: Ø125 mm/123 cm
2
cross section
Weight: 78 kg
Product measures: See fig. 1
Technical data according to EN 13240
Nominal heat output: 6,0 kW
Flue gas mass flow: 6,9 g/sec
Recommended chimney draught: 12 Pa
Efficiency: 71% @ 6,1 kW%
CO emission (13% O
2
): 0,28%
Flue gas temperature: 318
o
C
Operational type: Intermittent