4
Specifications
16 1/2”
21”
21”
15 1/4”
GF 100 DV Nordic QT
Specifications
Input Rates
Natural Gas
14,500 BTU/hr. maximum input
10,600 BTU/hr. minimum input
Propane
14,000 BTU/hr. maximum input
10,900 BTU/hr. minimum input
Inlet Pressure: MIN MAX
Natural Gas: 5.0 WC (1.24 kPa) 7.0 WC (1.74 kPa)
Propane: 11.0 WC (2.74 kPa) 13.0 WC (3.23 kPa)
Manifold Pressure: MIN MAX
Natural Gas: 2.2 WC (.55 kPa) 3.5 WC (.85 kPa)
Propane: 6.5 WC (1.59 kPa) 10.0 WC (2.49 kPa)
Piezo Ignitor / Standing Pilot
Weight: 150 lbs.
21”
22 1/4”
Hardware Bag Contents
Fuel Conversion Kit - LP................................ 154379
Exhaust Restrictor Plate ......................... 12934492
Wall Shield .................................................. 12948792
Ember Bag , 6 oz. ............................................ 129123
Flue Collar
Centerline
Suggested Tools for
Installation and Service
External regulator (for Propane only)
Piping which complies with local code
Manual shutoff valve (T-Handle in Massachusetts)
Sediment trap - if required by code
Tee joint
Pipe wrench
Pipe sealant
10 mm open end wrench
1/2”, 7/16” open end wrench or deep socket
Phillips head screwdriver
Flat head screwdriver
1/4” nut driver
4 mm allen wrench
Gloves
Safety glasses
Torx T20 screwdriver
Leak test solution
Reciprocating Saw
Power Drill