Fault Checks
(A)
Pump will not start:
(1) MANUAL TYPE
•
Power switched ON
•
Blown fuse (consult an electrician)
•
If * extension lead fitted check connection
•
Impeller jammed
•
Thermal cut out switch has not reset (5 minutes)
•
If pump does not start from new then the seal has possibly stuck due to the length of time it has been standing
since it was manufactured. In this case, remove bottomm strainer and turn the impellor nut clockwise with a pair
of pliers, this will release the initial friction on the. seal and once the power is connected will allow the pump to
work.
(2) AUTO TYPE (WITH FLOAT SWITCH)
•
Check all in (1) above
•
Float switch jammed against sump side wall
•
Insufficient liquid to place the float switch in the ON position i.e. higher than the horizontal
•
If fitting an extension lead a QUALIFIED ELECTRICIAN should be consulted to ensure correct rating is
provided.
If float switch is faulty a qualified electrician should replace. Float switches are available from your local Supplier.
(B) Pump will start but does not pump:
•
Insufficient liquid in sump
•
Strainer blocked
•
Impeller blocked
•
Impeller damaged
•
Entrained air present
•
Excessive back pressure
(C) Pump will not stop:
(1) MANUAL TYPE
•
Must be switched off at the power supply
(2) AUTO TYPE (WITH FLOAT SWITCH)
•
Float switch is prevented from moving to the fulyl down position
•
Float switch may be faulty
Do not run dry as this will damage the seal and reduce the life of the pump.
With simple cleaning and regular examination this pump should give many years of service.
For a full spares and repair service on any of our pumps send pump properly packed and post paid to
(D) • Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
•
Contact your local government for information regarding the collection systems available.
•
If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the
groundwater and get into the food chain, damaging your health and well-being.
•
When replacing old appliances with new once, the retailer is legally obligated to take back your old appliance
for disposal at least for free of charge.
(E) • Don't used in swimming pool.
•
Pollution of the liquid could occur due to leakage of lubricants.
•
pumps for outdoor fountains, garden p9nds and similar places have tobe supplied through a RCD
(operating current < 30 mA).
•
The supply cord connot be replaced, if the cord is damaged the appliance should be scrapped.
(F) • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
•
Children should be supervised to ensure that they do not play with the appliance.
•
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
•
The pump must not be used when people are staying in the water.
•
The pump must supplied through a residual current device (RCD) with a rated residual operating current < 30 mA.
•
Pollution of the liquid could occur due to leakage of lubricants,