JUDO QUICKSOFT-DUO 21
Data Sheet
9. Data Sheet
9.1 Type
JUDO QUICKSOFT-DUO Softener
Abbreviated name: JQS-D
Order No.: 8200320
9.2 Technical specifications
– Maximum ambient temperature and
water temperature: 30 °C (86 °F).
– The water to be softened must
conform to the European Drinking
Water Regulations!
– Threaded connection to DIN 2999.
The nominal pressure denotes the pressure
class, according to which the softener must
fulfil the requirements to DIN EN 14743 and
DIN 19636-100. The maximum operating
pressure is lower, in order to ensure the
optimum function of the softener.
For further information, please refer to the
“Diagrams” chapter.
Operating pressure
Nominal
pressure
2 - 7 bar (29 - 101.5 psi) PN 10
Operating weight when filled
with salt
approx. 60
kg
Shipping weight approx. 18
kg
Nominal flow rate up to 1.6 m³/h
Flow pressure at nominal
flow rate at least
2 bar
(29 psi)
Pressure loss at nominal
flow rate
1 bar (14.5
psi)
Short-term max. flow 3.5 m³/h
Pipe connection 1"
Nominal capacity 0.9 mol
Capacity per kg regenerat-
ing salt
5 mol
Salt container capacity 40 kg
Electrical connection 230 V/ 50
Hz
Power consumption:
Operation
Regeneration
1 W
max. 15 W