– 155 –
1
CN1 : Power input Power switch
CN3: Momentary interruption
detection signal MAIN board
CN2 : Power output MAIN board
Voltage changeover
Connected to 100V side
for 100V~120V or to
200V side for 200V~240V.
In the signal-phase mode, the
power supply is connected to
Pins 4-5. In the 3-phase mode,
the power supply is connected
to Pins 4-5-6.
7. Printed wiring board and dip switch
(1) Various printed wiring boards
1) FLT-T board Single-phase 100V~120V
3-phase 200V~240V
Pulse generation is carried out for the
purposes of power supply rectification,
noise reduction, and the detection of a
momentary interruption

Table of Contents