Document No.: JM/JMC5AA/0
OXYGEN CONCENTRATOR
JMC5A Ni
USER’S MANUAL
(Part No.:0209175 Rev. E Date: Sep.16.2019 )
DO NOT OPERATE THIS UNIT WITHOUT FIRST
READING AND UNDERSTANDING THIS MANUAL!
SAVE THIS MANUAL FOR FUTURE USE.

Questions and Answers

  • R
    Ronnie MunozAug 5, 2025
    How to fix JUMAO Medical Equipment when concentrator works, but yellow light illuminates?
    • F
      freemandennisAug 5, 2025
      If your JUMAO Medical Equipment concentrator's oxygen concentration is decreasing but still within a safe range, try cleaning or replacing the filters. Also, ensure the unit has enough ventilation by moving it at least 10 cm (4 inches) away from walls, draperies, furniture, or similar obstructions.
  • G
    greencynthiaAug 15, 2025
    What to do if the nasal cannula has more mirage or blobs in JUMAO Medical Equipment?
    • X
      xthomasAug 15, 2025
      If the nasal cannula of your JUMAO Medical Equipment has excessive mist or blobs, it could be due to several reasons: * Ensure the machine is at least 10 cm away from walls, other obstructions or heaters to ensure complete ventilation and prevent high operating temperatures. * Check the fan inside the machine. If it's not running or running slowly, take out the winker that locks the fan. * Make sure you add cold water to the humidifier bottle. * Ensure the water level in the humidifier bottle is between the maximum and minimum liquid levels.
  • S
    Sarah LiuAug 25, 2025
    How to troubleshoot JUMAO Medical Equipment that stops with lights and buzzer?
    • M
      Michelle RobinsonAug 26, 2025
      If your JUMAO Medical Equipment concentrator stops running immediately, the green and yellow lights are always on, and a continuous buzzer sounds, check the following: 1. Ensure the four corns plug-in of the valve is completely inserted. 2. If the exhaust sound buffer box is jammed, replace it. 3. If you can’t open the valve, replace it. 4. If the main electronic control circuit board has failed, replace it.

Summary

Safety Notes

Important Information

Essential safety warnings and precautions for operating the oxygen concentrator.

Before Installation

Guidelines for safe and proper installation of the oxygen concentrator.

Placement

Recommendations for optimal and safe placement of the oxygen concentrator unit.

Fire Warning and Explosion

Critical safety information regarding fire hazards and explosion risks.

Maintenance Safety

Safety instructions and warnings related to the maintenance of the oxygen concentrator.

Radio Frequency Interference

Information on potential radio frequency interference and precautions.

Risk Reduction

Instructions to reduce risks of burns, electrocution, fire, and personal injury.

Features

Summary

Overview of the JMC5A Ni oxygen concentrator's intended use and function.

Characteristics

Key features and components of the oxygen concentrator.

Specifications

Detailed technical specifications including power, flow, concentration, dimensions, and environmental conditions.

Handling

Unpacking

Step-by-step guide for safely unpacking the oxygen concentrator.

Inspection

Procedures for inspecting the oxygen concentrator for damage after unpacking.

Storage

Guidelines for properly storing the oxygen concentrator.

Installation and Operation

Feature View

Identification and explanation of the main components and controls of the oxygen concentrator.

Prepare Work

Steps to prepare the device and its accessories before operation.

Turning the Concentrator ON

Detailed instructions on how to power on and start the oxygen concentrator.

Alarm Signal

Explanation of the various alarm signals and their meanings during operation.

Alarm Signal Cue

Specific indicators for oxygen concentration levels using colored lights.

Turning the Concentrator Off

Procedures for safely powering down and unplugging the oxygen concentrator.

Symbols and Descriptions

Glossary of symbols used in the manual and on the device.

Maintenance

Cleaning the Cabinet

Instructions for regular cleaning of the exterior of the oxygen concentrator.

Filter Cleaning and Replacement

Guide for cleaning and replacing the different types of filters in the concentrator.

Cleaning the Optional Humidifier Bottle

Procedures for cleaning, disinfecting, and disassembling the humidifier bottle.

Nasal Cannula Maintenance

Guidance on maintaining or replacing the oxygen nasal cannula.

Tube Maintenance

Recommendations for maintaining or replacing internal tubing.

New Patient Preparation

Specific notes for preparing the unit for a new patient.

Other Attentive Items

Post-marketing Service

Details regarding warranty, free repair, and out-of-scope repair cases.

Waste and Residual Disposal

Guidelines for the proper treatment and disposal of waste and residuals.

Accessories and Spare Parts

Information on compatible accessories and spare parts for the oxygen concentrator.

Electromagnetic Environment Guidance

Guidelines for safe operation regarding electromagnetic emissions and immunity.

JUMAO JMC5A Ni Specifications

General IconGeneral
BrandJUMAO
ModelJMC5A Ni
CategoryMedical Equipment
LanguageEnglish