6.5 Filling time
The filling time for a battery depends on the electrolyte level, the ambient temperature
and the filling pressure. Filling ends automatically. The water supply line must be
disconnected from the battery when the water has been filled.
6.6 Water quality
Z The quality of the water used to fill up electrolyte must correspond to purified or
distilled water. Purified water can be produced through distillation or ion
exchangers and is then suitable for the production of electrolyte.
6.7 Battery tubing
The tubing of the individual plugs is in accordance with the existing electric circuit. No
changes should be made.
6.8 Operating temperature
Batteries with automatic water replenishment systems should only be stored in rooms
with temperatures > 0°C, as otherwise the systems could freeze.
6.9 Cleaning measures
The plug systems must only be cleaned with purified water in accordance with DIN
43530-4. No parts of the plugs must come into contact with solvent-based materials
or soap.
6.10 Service mobile vehicle
Mobile water filling vehicle with pump and filling gun to fill individual cells. The
immersion pump in the container generates the necessary filling pressure. The
service mobile must be at exactly the same height as the battery base.