Do you have a question about the Juta CM3024Z and is the answer not in the manual?
Check installation place safety rules and avoid hazardous conditions like wet or dusty environments.
Install controller vertically with 10cm spacing above and below for thermal dissipation.
Connect loads, battery, and solar panels in order; plug in thermal sensor and communication cable.
Dismantle solar panels, battery, loads first. Battery reversal causes safety risk to loads.
Describes graphical symbols displayed on the LCD screen for status indication.
Details the functions of the controller's physical buttons for navigation and operation.
Guides users on how to review and adjust various operational parameters.
Controller disconnects load when battery voltage is too low; reconnects when voltage recovers.
Controller limits load current to 1.2x rated; power is restored after removing loads.
Controller indicates short-circuit in load loop; check loads and cables and press button to recover.
Flickering indicates no solar panels detected; check connections and cables for open-circuit.
Details key parameters like rated voltage, current, temperatures, dimensions, and weight.
| Model | CM3024Z |
|---|---|
| Rated charging current | 30A |
| Output Current | 30A |
| System voltage | 24V |
| Input Voltage | 24V |
| Protection | Overload protection, Short circuit protection, Reverse polarity protection |
| Operating Temperature | -20°C ~ +55°C |
Loading...