No. 52023
V-21DMT3/AV-21D
V-2135TEE/AV-2135EE
V-21DMG3
21
Item
Measuring
instrument
Test point Ad justment part Description
Ad just ment
of DELAY
POI NT
(AGC)
Signal
generator
Remote
control unit
DELAY POINT
(AGC TAKE-OVER)
1. Input a blac k an d wh it e signal (colo ur of f).
2. En ter th e SERVICE MENU.
3. Select 1. IF f rom t he SERVI CE MENU.
4. Select 2. DELAY POINT b y pressin g the 2 key on the remote
control unit.
5. Set the settin
valu es of th e set tin
item s as s ho wn bello w t able .
6. Then adjust the MENU - or + key until video noise disappears.
7. Tur n to oth er ch an nels and make su re that the re are n o
irregularities.
Setting Item Variabl e range Initial setting value
MATSUSHITA
QAU0287-001
MURATA
QAU0185-004
ALPS
QAU0282-001
NT SC 3.5 8
45 45 45
DELAY POINT
(AGC TAKE OVER)
OTHER
0~127
35 45 35
DELAY POINT UHF
AGC TAKE-OVER
**
- / + : OPERATE DISP : EXIT