Questions and Answers

  • M
    Michele SalasAug 7, 2025
    How to fix Kabola B-12 burner that won’t start?
    • J
      Jamie RichardsAug 7, 2025
      If the Kabola Boiler burner won’t start, it might be due to an interrupted oil supply. Try bleeding the oil filter, changing a contaminated filter element, and filling the oil tank. Alternatively, the power supply might be interrupted; in that case, check the fuses and the power supply.
  • H
    hurleyashleeAug 12, 2025
    What to do if Kabola Boiler burner shows error?
    • B
      Brian SimonAug 12, 2025
      If the Kabola Boiler burner shows an error, try resetting the burner. Also, check the voltage level, as low voltage could be the cause. If the issue persists, the oil supply may be interrupted.
  • D
    Deanna KimAug 17, 2025
    Why does my Kabola B-12 burner keep stopping?
    • R
      richardsonjustinAug 17, 2025
      If the Kabola Boiler burner stops, it could be due to a dirty or defective flame protection (photo cell). Try resetting the burner and cleaning the glass of the flame protection. If that doesn't work, consider replacing the flame protection.
  • T
    Thomas SimonAug 22, 2025
    Why is my Kabola Boiler burner pulsing?
    • D
      Devin WilsonAug 22, 2025
      If the Kabola Boiler burner starts pulsing, it may be due to an interrupted flue gas flow. Clear the chimney opening to resolve this. Alternatively, the boiler might be dirty, so clean it. A defective nozzle can also cause pulsing, so replace the nozzle if necessary. The oil supply may also be interrupted.
  • J
    Jeremy CallahanAug 27, 2025
    What to do if Kabola B-12 does not react to thermostat?
    • T
      Tyler SanchezAug 27, 2025
      If the Kabola Boiler does not react to the thermostat, ensure that the wire in the main connector has been removed if a room thermostat is installed. Check that the boiler thermostat is correctly adjusted. Also, replace the battery of the room thermostat, if it's empty.
  • J
    Jonathan OlsenSep 1, 2025
    What to do if water is not pumped in Kabola B-12?
    • R
      Robin LopezSep 1, 2025
      If water is not being pumped in your Kabola Boiler, first check if the pump couplings are closed and open them. Then, ensure the pump is connected to the power supply. If the rotor of the pump is stuck, turn the pump with your hand.

Summary

Safety

General safety

General safety warnings and user responsibilities for boiler operation.

Safety instructions

Specific safety instructions for installation and operation.

Installation and preparation for first use

Installation

Guidelines for the correct placement and fitting of the boiler.

Flue gas outlet

Crucial information on installing the flue gas outlet for efficiency and safety.

Electrical installation

Instructions for connecting the boiler to the electrical supply.

Operating the boiler

Cleaning and maintenance

Appendix A Technical specifications

Appendix C Electrical diagram B8-B70 230 V

Appendix D Electrical diagram B80-B100 230 V

Appendix E Electrical diagram B8-B45 24 V

Appendix F Troubleshooting

Kabola B-12 Specifications

General IconGeneral
BrandKabola
ModelB-12
CategoryBoiler
LanguageEnglish

Related product manuals