The ECONOMY MODE switch must be set to “OFF” to increase
engine speed to nominal. When connecting multiple power
consumers to the generator, be sure to first connect the one
with the highest starting current, and the device with the
lowest starting current should be connected last.
IMPORTANT!
ECONOMY MODE FUNCTION (EXCEPT FOR MODEL KSB 30ECONOMY MODE FUNCTION (EXCEPT FOR MODEL KSB 30ii S) S)
FUNCTIONAL DESCRIPTION OF INVERTER GENERATORS
8
The ECONOMY MODE switch must be set back to “OFF” when
using electrical devices requiring a high starting current, such as
a compressor or submersible pump.
IMPORTANT!
“ON” MODE“ON” MODE
When the ECONOMY MODE switch is in the “ON” position, the control unit monitors the engine speed, reducing it
commensurate with the connected load. If the engine speed is not enough to generate electricity to provide the load,
the control unit will automatically increase the engine speed.
As a result, fuel consumption is optimized and noise levels are reduced.
“OFF” MODE“OFF” MODE
The ECONOMY MODE switch must be set back to “OFF” when using electrical devices requiring a high starting current,
such as a compressor or submersible pump.
PARALLEL FUNCTION FOR MODEL KSB 21PARALLEL FUNCTION FOR MODEL KSB 21ii S S
You can increase the total output power of the generators by connecting the two inverter generators together with
special cables for parallel connection of KSB PC-1 from K&S Basic
®
(not included in a set). Parallel connection of two
Do not connect two or more devices at a time. The start-up of
many devices requires high power. Devices should be connected
one at a time according to their power rating. Do not connect any
power consumers within the rst 2 minutes after the generator
has been started.
ATTENTION – DANGER!
Useful tip: to ensure long-term operation of the generator en-
gine, it is important to observe the following tips:
- Before connecting the load, allow the engine to run for 1-2 minutes to warm it up.
- When disconnecting the load after lengthy operation, do not turn o the generator. Allow the
generator to run idle for 1-2 minutes so that it cools down.
IMPORTANT!
5. In this position:
a. Fuel system is on. b. Ignition circuit is on. c. Battery power is on d. Air choke closes and generator is ready to start
with a cold engine. (If the engine is warm, immediately turn the 3-in-1 switch to the “ON” position).
5.1. For manual start pull the manual starter until a slight resistance is felt, then pull it toward you relatively sharply.
Slowly turn the manual starter by hand, do not release it abruptly.
5.2. For electric start (KSB 40iE S model) - Turn the 3-in-1 switch to the «Air Choke» position, then press the ENGINE
START button, Turn the 3-in-1 switch to the ON position when the engine warms up. To ensure long-term operation
of the battery, do not press the ENGINE START button for more than 3 seconds. There must be an interval of at least
10 seconds between startup attempts.
6. Set the 3-in-1 switch to “ON” (Fig. 2).
1. Start the engine.
2. Set the ECONOMY MODE switch to “ON”.
3. Plug the device into an AC outlet.
4. Make sure the AC indicator light is on.
5. Turn on the electrical device.
konner-sohnen.com | 9