Useful tip: to ensure long-term operation of the generator engine, it
is important to observe the following tips:
- Before connecting the load, allow the engine to run for 1-2 minutes to warm it up.
- When disconnecting the load after lengthy operation, do not turn off the generator. Allow the generator
to run idle for 1-2 minutes so that it cools down.
IMPORTANT!
Do not connect two or more devices at a time. The start-up of many
devices requires high power. Devices should be connected one at
a time according to their power rating. Do not connect any power
consumers within the rst 2 minutes after the generator has been
started.
ATTENTION – DANGER!
ECON FUNCTIONECON FUNCTION
1. Start the engine.
2. Set the ECON switch to “ON”.
3. Plug the device into an AC outlet.
4. Make sure the AC indicator light is on.
5. Turn on the electrical device.
FUNCTIONAL DESCRIPTION
OF INVERTER GENERATORS
8
Lösen Sie bei Modelle KSB 22i S die 2 Schrauben an
der Seitenwand mit einem Schlüssel #8. Lösen Sie die
Ablassschraube C am Vergaser und lassen Sie den ver-
bleibenden Kraftsto durch das Rohr D in die dafür
vorgesehene Tropfschale ablaufen. Benzinlecks sollten
vermieden werden. Ziehen Sie die Schraube fest. Brin-
gen Sie den Gehäusedeckel des Generators wieder an.
Lassen Sie den Generator mit Flüssiggas laufen.
С
D
KSВ 22i S
The ECON switch must be set to “OFF” to increase engine speed
to nominal. When connecting multiple power consumers to the
generator, be sure to first connect the one with the highest starting
current, and the device with the lowest starting current should be
connected last.
IMPORTANT!
“ON” MODE“ON” MODE
When the ECON switch is in the “ON” position, the control unit monitors the engine speed, reducing it commensurate
with the connected load. If the engine speed is not enough to generate electricity to provide the load, the control unit will
automatically increase the engine speed.
As a result, fuel consumption is optimized and noise levels are reduced.
“OFF” MODE“OFF” MODE
The ECON switch must be set back to “OFF” when using electrical devices requiring a high starting current, such as a
compressor or submersible pump.
The ECON switch must be set back to “OFF” when using electrical
devices requiring a high starting current, such as a compressor or
submersible pump.
IMPORTANT!
DISCONNECT ALL DEVICES BEFORE STOPPING THE GENERATOR!DISCONNECT ALL DEVICES BEFORE STOPPING THE GENERATOR!