COMMANDS
15
CWTone n (n = 50 – 2000)
default 750 KAM CW
This command sets the CW filter center frequency (in Hertz) for receiving CW.
DAytime yymmddhhmmss
All Units Packet
If the parameter yymmddhhmmss is present, the software clock/calendar is set for MHEARD and
NDHEARD logging, and CSTAMP and MSTAMP functions. When entering the daytime digits enter in
pure number sequence with no spaces, dashes, or slashes. For example: 860102223000 would in-
dicate 1986, January 2, at 22:30:00 hours. If DAYTIME is entered with no parameter the daytime
is displayed in a form depending on the setting of the DAYUSA flag. If the SmartWatch option is in-
stalled, a setting of DAYTIME 000000000000 will turn it OFF.
See also: cstamp, dayusa, mheard, mstamp
DAYTWeak n (n = 0 – 15)
default 8 All Units Packet/WEFAX
This parameter is used to tweak the clock for accurate time keeping. Increasing the parameter will
slow the clock, decreasing the parameter will speed up the clock. Each count corresponds to .85
seconds increase or decrease per day. Ambient temperature will affect the clock to some degree. If
WEFAX pictures are skewing, use this command to adjust the clock speed of the TNC.
DAYUsa ON | OFF
default ON
When ON, the daytime stamp is displayed in the form common in the USA: month/day/year. When
OFF, the daytime stamp is displayed in the form common in Europe: day/month/year.
See also: daytime
DBldisc ON | OFF V 2.3
default OFF All Units Packet
When OFF, only one disconnect command (D) need be sent to terminate an unsuccessful connect
attempt. If you are actually connected, the normal disconnect sequence will occur. When ON, a
normal disconnect sequence will always occur (you will not be disconnected until you receive an
acknowledge of your disconnect or until the retry count is exceeded). A second D is required to
force a local disconnect independent of the retry counter.