9. TECHNICAL DATA
Power Connection
Voltage .............................................................220-240 V-AC
Current..............................................................1~50/60 Hz
Connected/Load ....................................................... 1.6 KW
Mains Fuse ................................................................ 13 AMP
Water Connection
Supply Temperature (Max)........................................ 40 °C
Supply Rate (Min) .................................................... 600 litres per hour
Supply Pressure (Max) .............................................. 12 bar
Supply Hose Length ................................................. 7.5 metres
Diameter .............................................. 1/2 inch
Performance Data
Max. Pressure ......................................................... 100 bar
Rated Pressure.......................................................... 90 bar
Flow Rate................................................................. 360 litres per hour
Detergent Intake ........................................................ 25 litres per hour
Recoil Force of Hand Held Spray Gun
at Operating Pressure (Max) ..................................... 13 N
Unit vibration............................................................. 0.8 m/s²
Optimum Working Distance on High Pressure .......... 30 cm
Noise Level L
PA
(EN 60704-1).................................... 77 dB(A)
Guaranteed Sound Power Level L
WA
(EN ISO 4871) ... 92 dB(A)
Dimensions
Length...................................................................... 410 mm
Width ....................................................................... 220 mm
Height ...................................................................... 900 mm
Weight ......................................................................... 6 Kg
Circuit Diagram
M1 Motor
Q1 Appliance switch
S1 Pressure-operated switch
Z 1 Suppressor