Pressure | 110 bar |
---|---|
Flow rate | 500 L/h |
Power | 2.2 kW |
Voltage | 230 V |
Frequency | 50 Hz |
Hose Length | 10 m |
The overflow valve prevents the permissible working pressure from being exceeded.
If the trigger gun lever is released, the pressure switch turns off the pump, stopping the high-pressure jet.
Check the contents of the pack before unpacking. Inform the vendor immediately of any transport damage.
Danger of electric shock. Appliance must only be connected to alternating current and properly installed electrical supply.
Observe water supplier regulations. Use a system separator for drinking water supply connections to prevent contamination.
Deaerate the appliance by unscrewing the nozzle and running until water is bubble-free.
Close the hand spray gun. Turn the nozzle casing until the desired symbol matches the marking.
Use only Kärcher approved detergents to avoid damage to the appliance and object being cleaned.
Spray detergent sparingly on dry surface, let react but not dry. Spray off dirt with high-pressure ray.
Consider signing a contract with your dealer for regular safety inspection or maintenance services.
Check connection cable for damages (risk of electrical shock) and replace if damaged by authorized service.
Check connection cable, supply voltage. Call Customer Service for electrical defects or issues not covered.
Ensure correct nozzle, clean/replace nozzle, de-aerate appliance, check water supply, and inlet pipes.
Minor leaks (3 drops/min) are normal. Call Customer Service for heavy leakage or issues with stronger leaks.
Check suction pipes for water and detergent and ensure they are leak-proof. Operate without detergent if necessary.
Set nozzle to 'CHEM'. Check/clean detergent suction hose with filter. Check/clean detergent dosing valve.