English Operating Instructions HD 994... / HD 1094... / HD 1294...
17
Water connection/Suction
feed operation
Connection to water main
Caution!
Pay attention to the regulations of the
water supply company; according to DIN
1988, the cleaner may not be connected
direct to the public drinking water supply.
A short-term connection via a non-return
valve (Order no. 6.412-578) is allowed.
Dirty water may damage the unit. To prevent
this, we recommend using a water filter, 1”
connection (order no. 2.638-270).
For connected loads see Technical
Specifications.
n
Connect a supply hose (not supplied) to the
water outlet on the cleaner and to the water
inlet (e.g. water tap).
n
Open water inlet.
Suctioning water from an open container
n
Screw suction hose with filter (Order no.
4.440-238) to the water outlet.
n
Evacuate air from the cleaner before
operating it
To vent the unit, unscrew the nozzle and
leave the unit running until the water
exits with no air bubbles.
Switch off the unit and screw the nozzle
back on.
Operating the cleaner
Danger!
Observe the relative safety regulations
when using the cleaner at filling stations or
other high-risk areas.
Caution!
Only clean engines in places which
have appropriate oil separators (protection of
the environment).
Caution!
Only wash animals with the low-
pressure fan jet (see ”Selecting the type of
spray”).
Operating with high pressure
The cleaner is equipped with a pressure
switch. The motor only starts up when the
lever is retracted.
n
Unroll the required length of high-pressure
hose from the hose reel.
n
Release the handgun with the pressure
and flow control and pull the handgun
lever.
n
Set unit switch to ”I”.
n
Adjust operating pressure and flow rate
(+/–) by rotating the pressure/flow control
(infinitely variable).
Read off operating pressure on pressure
gauge.
n
At the lowest flow rate the waste heat from
the motor will heat the water to approx.
15 °C.
!