457462_b 63GB
Fault code Cause Remedy
CN007: No loop sig-
nal
No loop signal
The boundary cable is
faulty.
Loop signal is too weak.
Check the LEDs on the charging
station.
Check the power source of the
charging station. Disconnect and re-
connect the power supply.
Check the boundary cable for dam-
age. Repair the defective cable.
CN008: Loop signal
weak
Loop signal too weak
Boundary cable buried
too deep
Check the LEDs on the charging
station.
Check the power source of the
charging station. Disconnect and re-
connect the power supply.
Raise the boundary cable to the
prescribed height; attach directly on
the grass if necessary.
CN010: Bad position
The appliance is outside
the designated grass
surface.
The boundary cable has
been routed in a criss-
cross pattern.
Place the appliance on the free,
designated grass surface.
Correct the location of the boundary
cable around curves and obstacles.
Eliminate the criss-crossing of the
cable.
CN011: Escaped robot The appliance is outside the
designated grass surface.
Correct the location of the boundary ca-
ble around curves and obstacles.
CN012: Cal: no loop
CN015: Cal: outside
Fault during the calibration:
The appliance cannot
find the boundary cable.
Check the LEDs on the charging
station.
Check the power source of the
charging station. Disconnect and re-
connect the power supply.
Place the appliance at the pre-
scribed calibrating position; align
precisely at right angles. Appliance
must be able to drive over the
boundary cable.
CN017: Cal: signal
weak
Fault during the calibration:
Loop signal too weak
No loop signal
The boundary cable is
faulty.
Place the appliance at the pre-
scribed calibrating position; align
precisely at right angles.
Check the power source of the
charging station. Disconnect and re-
connect the power supply.
Check the boundary cable for dam-
age.
CN018: Cal: Colli-
sion
Fault during the calibration:
The appliance has
bumped into an obstacle.
Remove the obstacle.