Page #7 background imageLoading...
Page #7 background image
English 7
Caution
Make sure that the power cable or ex-
tension cables are not damaged by run-
ning over, pinching, dragging or similar.
Protect the power cable from heat, oil,
and sharp edges.
Never fill solvents, solvent-containing
liquids or undiluted acids (e.g. deter-
gents, benzene, paint thinner, and ace-
tone) into the water reservoir as these
substances affect the materials used on
the appliance.
The appliance must not be carried dur-
ing cleaning.
The appliance must provide of a stable
ground.
Use and store the unit only in accord-
ance with the specifications in the de-
scription and/or figure.
The steam switch must not be locked
during the operation.
Protect the appliance from rain. Do not
store outside.
Caution
Safety devices protect the user and must
not be modified or bypassed.
The pressure controller keeps the boiler
pressure during the operation as constant
as possible. The heating is turned off if the
maximum operating pressure of 4 bar is
reached in the boiler and is reactivated in
case of a pressure drop in the boiler due to
steam tapping.
If, in case of a malfunction, there is no wa-
ter in the boiler, the temperature in the boil-
er rises. The boiler thermostat turns off the
heating. Once the boiler is filled, normal op-
eration can continue.
The safety thermostat turns off the appli-
ance if the boiler thermostat and the pres-
sure controller fails and the appliance
overheats in case of a malfunction. Please
contact your local KÄRCHER customer
service to arrange for the reset of the safety
thermostat.
The maintenance lock acts as a pressure
control valve at the same time. It seals the
boiler against the steam pressure that
builds up in the boiler.
If the pressure controller is defect and the
steam pressure in the boiler rises, the pres-
sure control valve, and steam is emitted
through the maintenance lock to the out-
side.
Please contact your local KÄRCHER cus-
tomer service before you put the appliance
into operation again.
Safety devices
Pressure controller
Boiler thermostat
Safety thermostat
Maintenance lock

Other manuals for Kärcher SC 4.100 CB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kärcher SC 4.100 CB and is the answer not in the manual?

Kärcher SC 4.100 CB Specifications

General IconGeneral
AC input voltage220 - 240 V
TypeCylinder steam cleaner
Capacity1 L
Ready time3 min
Steam pressure3.5 bar
Soft gripYes
Dimensions (WxDxH)241 x 384 x 275 mm
Weight and Dimensions IconWeight and Dimensions
Weight4200 g