3.4 TRIMPOT ADJUSTMENTS
• Minimum Speed (MIN) – Sets the minimum speed of the motor. See Section 13.1 on page 29.
• Maximum Speed (MAX) – Sets the maximum speed of the motor. See Section 13.2 on page 29.
• Acceleration (ACCEL) – Sets the amount of time for the motor to accelerate from zero speed to
full speed. See Section 13.3 on page 29.
• Deceleration (DEC/I) – Sets the amount of time for the motor to decelerate from full speed to
zero speed. See Section 13.4 on page 27.
• DC Injection Brake (DEC/I) – When the drive is set for DC Injection Braking (Jumper J7 set to
the “INJ” position), the DEC/I trimpot is used to set the DC Injection Brake voltage and time.
See Section 13.5 on pages 29 and 30.
• Slip Compensation (COMP) – Maintains set motor speed under varying loads. See Section 13.6
on page 30.
• Current Limit (CL) – Sets the current limit (overload) which limits the maximum current to the
motor. See Section 13.7 on pages 30 and 31.
• Boost (BOOST) – Sets the amount of Boost which can be used to obtain maximum low speed
performance. See Section 13.8 on pages 31 and 32.
• Jog (JOG) – Sets the “jog” speed of the motor. Must be used with the optional Run-Stop-Jog
Switch Kit (See Table 2 on page 9). See Section 13.9 on page 32.
Table 1 – Jumper Selectable Features
Description
1
PC Board
Designation KBAC-24D, 27D KBAC-29, 29 (1P), 45, 48
KBAC-217 Series
KBAC-416 Series
AC Line Input Voltage (115, 230) J1
p
— —
Motor Horsepower (see Table 4 - Electrical Ratings on page 14) J2
p p p
Automatic Ride-Through or Manual Restart (A
2
, M) J3
p p p
Frequency Multiplier (1X, 2X) J4
p p p
Motor Frequency (50Hz, 60Hz) J5
p p p
Fixed or Adjustable Boost (FIX, ADJ) J6
p p p
Regenerative or DC Injection Braking (RG, INJ) J7
p p p
“Run” or “Fault” Output Relay Operation (R, F) J8
p p p
Normally Open or Closed Stop Contact (NO, NC) J9
p p p
Constant or Variable Torque (VT, CT) J10
p p p
Factory Use Only J11 — — —
Switching Frequency and GFCI (8 kHz, 12 kHz, G1, G2) J12 — —
p
Notes: 1. Bold indicates factory setting. 2. In Automatic Ride-Through Mode, the drive will automatically restart due to a momentary power loss of
less than 2 seconds.