P30 Assistance in case of problems
FAQ V1.01
27
© KEBA
LED bar Cause Measure
The charging station has de-
tected a short circuit.
Check cable and plug for dam-
age and replace defective com-
ponent.
If the error persists: Contact a
service technician
The charging station has de-
tected a configuration error.
Check the DIP switch settings for
correct configuration and restart
the charging process (see the
"Installation Manual").
The charging station has de-
tected an invalid cable. For com-
patibility reasons, the charging
station does not accept charging
cables with a charging current of
13 A or less.
Use a charging cable with a
higher charging current.