Operation Manual ServoOne Supply Unit
50
ID no.: 1101.21B.6-00 Date:04/2020
On a supply unit BG7 the DC connection X11/ZK is not protected internally.
––
ZK
++
ZK PE PE
ServoOne
Versorgungseinheit BG7
mit Flüssigkeitskühlung
––
ZK
++
ZK PE PE
ServoOne DC BG7
mit Flüssigkeitskühlung
++
ZK
––
ZK
ServoOne DC BG6a
mit Flüssigkeitskühlung
F2
1)
2)
2)
+
+
1)DCfusesrequired.
2)FortheconnectionoffurtheraxiscontrollersBG5andsmaller,seeFigure4.22)
Figure 4.24 Schematic: connection, DC power supply, BG7 to BG6a/ BG7.
ServoOne DC BG 6a
X11
++
ServoOne
Versorgungs-
einheit BG 6a
X11
+
X12
+L3L2L1PE
-
RB
ZK
+
2)
1)
3)
1)Shortestconnection
2)Alternatively,theDClinkconnectiononterminalX12canbeused.
3)FortheconnectionoffurtheraxiscontrollersBG5andsmaller,seeFigure4.22
Figure 4.23 Schematic: connection, DC power supply, BG6a to BG6a
Electrical installation