EasyManua.ls Logo

Keba SO84.115.S - Order Code; Data on Manufacture; Scope of Supply

Keba SO84.115.S
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual ServoOne Supply Unit
8
ID no.: 1101.21B.6-00 Date:04/2020
General
1.4 Order code
The supply unit (SOVE) has the article designation SO84.xxx.S0xx.xxxx.x. This provides
information on the related variant of the SOVE supplied. The signicance of the individual
characters of the article designation is given in the following order code.
Article
designation
SO8 4 . 040 . S 0 0 0 . 0 0 0 0 . X
ServoOne
Supply voltage: 3 x 400V 4
Rated current
BG5
40A
76A
040
076
BG6a
115A
170A
115
170
BG7
375A
540A
375
540
DC supply unit regenerative S
Option 1 Communication Not included
SercosII
PROFIBUS
EtherCAT
CANopen
CANopen + 2AO
PROFINET IRT
SercosIII
Powerlink
1)
0
1
2
3
4
5
7
8
9
Option 2 Technology Not included 0
Housing/cooling method Air-cooled
Liquid-cooled with internal braking resistor
Liquid-cooled
0
7
8
Function package Basic (without additional function package)
iPlc
1
Special design None 0
Protection PCBs with protective varnish 1
Hardware version (May be multi-digit) X
1) in preparation
1.5 Data on manufacture
On the rating plate for the SOVE you will nd the serial number, from which you can
identify the date of manufacture based on the following key. For the location of the rating
plate on the SOVE refer to chap. 4.3 FF.
SN.: JJWWxxxxxSN.: JJWWxxxxx
Year of production
Week of production
Figure 1.1 ServoOne hardware rating plate
1.6 Scope of supply
The scope of supply includes:
y ServoOne supply unit
y Pre-assembled DC link cables up to BG5
y Product DVD with booklet (safety and application instructions for electrical equipment in
25languages)
Mains connection set required
The mains connection set is required for the intended use of the ServoOne supply unit.
The scope of supply includes:
y Mains lter
y Input choke with lm capacitor
y Step-up choke
y Shield plates and clamps (only for the sizes BG5 and BG6a)

Table of Contents