2260B Series User Manual 
140 
Series and Parallel Capability 
Up to 3 units including the master unit 
Up to 2 units including the master unit 
Temperature Coefficient: (after a 30 minute warm-up) 
10%  to 110% of rated output voltage 
±(Rated output voltage x 2%) 
10%  to 110% of rated output current 
±(Rated output current x 2%) 
Activated by elevated internal temperatures 
Analog Programming and monitoring (at 23˚C±5˚C) 
Accuracy & linearity = +/-0.5% of rated Vout 
Accuracy & linearity = +/-1% of rated Iout 
Accuracy & linearity = +/-1.5% of rated Vout 
Accuracy & linearity = +/-1.5% of rated Iout 
Front Panel Display Accuracy: 4 digits (at 23˚C±5˚C) 
Environmental 
Conditions: 
20% to 85% RH; No condensation 
90% RH or less; No condensation 
Type A: Host, Type B: Slave, Speed: 1.1/2.0, USB 
Class: CDC(Communications Device Class) 
MAC Address, DNS IP Address, User Password, 
Gateway IP Address, Instrument IP Address, 
Subnet Mask 
Optional: 2260B-GPIB-USB (GPIB to USB Adapter)