EasyManuals Logo
Home>Keithley>Power Supply>2260B-80-13

Keithley 2260B-80-13 Quick Start Guide

Keithley 2260B-80-13
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
OPERATION
25
5. Press the Voltage knob to save the
configuration setting. ConF will be
displayed when successful.
Voltage
6. If CC Slew Rate Priority was chosen as the
operating mode, set F-06 (Rising Current Slew
Rate) and F-07 (Falling Current Slew Rate) and
save.
F-06 / F-07
0.01A/s~72.00A/s (2260B-30-36)
0.1A/s~144.0A/s (2260B-30-72)
0.1A/s~216.0A/s (2260B-30-108)
0.01A/s~27.00A/s (2260B-80-13)
0.01A/s~54.00A/s (2260B-80-27)
0.01A/s~81.00A/s (2260B-80-40)
0.001A/s~9.000A/s (2260B-250-4)
0.01A/s~18.00A/s (2260B-250-9)
0.01A/s~27.00A/s (2260B-250-13)
0.001A/s~2.880A/s (2260B-800-1)
0.001A/s~5.760A/s (2260B-800-2)
0.001A/s~8.640A/s (2260B-800-4)
7. Press the Function key again to
exit the configuration settings.
The function key light will turn
off.
8. Use the Voltage knob to set the
voltage limit (crossover point).
Voltage