JS PRESSURE RELIEF VALVES
© 2017 Kelso Technologies (USA) Inc. All Kelso Valves are Patent Protected. Detailed designs are subject to change without notice.
Kelso Technologies Inc. 1526 Texas Ave, Bonham, TX. 75418, Phone: (903) 583-9200
Document No. - KTUD112
Revision 6 2/7/2022 (Original Release 12/7/2015)
www.kelsotech.com
Printed in U.S.A.
3. Figure 6.7 specifies the AAR allowable tolerances for the STD and VTP of
each valve model covered in this document. Depending on the initial STD
observed, proceed with the following adjustments:
a. If the pressure indicated is below the acceptable AAR tolerance for
valve setting, rotate the adjustment screw clockwise and test again.
Repeat this process until the desired STD value has been established
then record the pressure (Figure 6.8 & 6.9).
Valve Model
STD
VTP (Minimum)
JS75/75S
72-78 psi
60 psi
JS75XL/XLS
72-78 psi
60 psi
JS75L/75LS
72-78 psi
60 psi
JS165L/165LS
161-169 psi
132 psi
JS75H/HS/XH/XHS
72-78 psi
60 psi
JS165H/HS
161-169 psi
132 psi
Figure 6.3
Figure 6.4
Figure 6.5
Figure 6.6
Figure 6.7