EasyManua.ls Logo

Kemper TRESOR - Detailed Component Installation; Frost-Proof Outer Fitting Installation (Exposed;Concealed); Trim Frame with Door Installation

Kemper TRESOR
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 / 16 K410021000001-00 / 09.2021 – © www.kemper-olpe.de
Push the trim frame with door (8) with the lateral guide slots over
the (pre-assembled) screws, until the frame lies flush with the
outer wall of the building.
Then secure the trim frame with door (8) using the screws.
1.
2.
The integral flap for hose and cable connection is for safety purposes
during use.
5
Installation of the trim frame with door
to the built-in wall cabinet
4
Installation of frost-proof outer fitting
and spray protection
1.
2.
3.
Insert the frost-proof outer fitting (3) into the hole and attach
using the two M6 screws (4) provided.
Connect the outer fitting (3) to the water supply
(copper pipe Ø 15 mm or AG R ½“)
Insert the spray protection plate (9) with the central hole (Ø
35 mm) below the frost-proof outer fitting, and connect to the
attachment points provided on the rear wall using the M6 screws
provided (10).
Note!
The valve seat (thread R ½“) must be located in the frost-
free area.
Note!
The specifications given under Point 1 Minimum wall
thicknesses must be observed!
Exposed installation
Concealed installation