5. TROUBLE SHOOTING
See also 2.7. Overheat signal lamp.
Overheat signal lamp is lit.
The unit is overheated.
• Check water circulation.
• Check that there is enough free space behind the machine for cooling air
circulation.
Error code Err 5/Err 27 on the panel
• Check the liquid hoses for damages.
• Remove any hose blockages.
• Check water circulation, add liquid if needed.
For further information and assistance, contact your nearest Kemppi service
workshop.
6. TECHNICAL DATA
Cooling unit KempCool 10
Operating voltage
400V -15%. …+20%
Connection capacity
100 % ED 250 W
Cooling power
1 kW
Start pressure, max.
0.4 MPa
Cooling liquid
20 % – 40 % etanol/water
Tank volume
3 l
External dimensions
LxWxH 570x230x280 mm
Weight
11 kg
Operating temperature range
-20 … +40 °C
Storage temperature range
-40 … +60 °C
EMC class
A
Degree of protection
IP23S
88 KempCool 10