Pro 3200 Evolution, Pro 4200 Evolution, Pro 5200 Evolution/0109 – 13
© COPYRIGHT KEMPPI OY
8. ORDERING NUMBERS
Pro 3200 Evolution 6131320
Pro 4200 Evolution 6131440
Pro 5200 Evolution 6131520
Return current cable 5 m - 50 mm
2
6184511
Return current cable 5 m - 70 mm
2
6184711
Cable for MMA welding 5 m - 50 mm
2
6184501
Cable for MMA welding 5 m - 70 mm
2
6184701
PL 6185801
PX 6185802
R10 6185409
R20 6185419
Remote controlled interconnecting cable 10 m 6185481
T10 6185231
T120 6185252
P40 6185264
P40L 6185264L
P30W 6185262
7.3. UNDER- AND OVERVOLTAGES IN THE MAINS SUPPLY
Primary circuits of machine are protected against sudden, transient overvoltages.
Machine is designed to withstand 3 x 440 V voltage continiously (see technical data). See to
it that voltage is kept within admissble limits especially when mains supply is taken e.g. from
combusition engine generator.
If the mains has undervoltage (under approx. 300 V), machine control stops to operate automa-
tically.
7.4. LOSS OF A PHASE IN THE MAINS SUPPLY
Loss of a phase causes noticeable poorer welding properties than normally or the machine
doesn’t get started at all. Loss of a phase can be due to following:
- blowing of mains supply fuse
- defective mains cable
- bad connection of mains connection cable on terminal block or plug of machine