INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Clearances and Dimensions
1. Provide adequate clearances between the range and adjacent combustible surfaces.
2. LocationmCheck location where the ranqe will be installed. Check for proper electrical supply, and the stability of the floor.
3. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be solid
and level.
RANGE RANGEELECTRICAL FRONT..................TYPICALCABINETINSTALLATION SIDE
OVERALL CONNECTIONS VIEW
DIMENSIONS
25-3/4"
_1---- 30" 30"
Minimum 1÷13"-*
Minimumto 1" -_" ÷ _| / Minimumto _
wallon either 18" cabinetson Maximumdepth
sideof range ® _ _'_ ®® eitherside for cabinets
above36"height. _1, ofrange, aboverangetop.
8 ...........................................................
" \ Wall
\\,4_.29-7/8" .'_.> . Edge
Door Open \ _ t _ / - - t _ 2-5/8"for modelsequipped
._J-J- / withwarmerdrawers.
3-1/2"for modelsequipped 30"
Fig. 1 ** Depth is 28-13/32"with door handle, with storagedrawers Fig. 2 Fig. 3 _'_ _ 0" clearancebelow cookingtop and at rearof range.
*30"MINIMUMCLEARANCEBETWEENTHETOP OFTHECOOKINGSURFACEAND THE BOTTOMOFAN UNPROTECTEDWOODOR METAL
CABINET;OR24" MINIMUMWHEN BOTTOMOF WOODORMETALCABINET IS PROTECTEDBY NOTLESSTHAN 1/4"FLAME RETARDANT
MILLBOARDCOVEREDWITHNOTLESSTHAN NO.28MSGSHEETSTEEL,0.015"STAINLESSSTEEL,0.024"ALUMINUMOR0.020"COPPER.
0" CLEARANCE IS THE MINIMUM FOR THE REAR OFTHE RANGE. FOLLOW ALL DIMENSION REQUIREMENTS PROVIDED ABOVE TO
PREVENTPROPERTYDAMAGE, POTENTIAL FIRE HAZARD,AND INCORRECT COUNTERTOPAND CABINET CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE SPACE LOCATED
ABOVE THE SURFACE UNITS SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE PROVIDED, THE RISK CAN BE REDUCED BY
INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5" BEYOND THE BOTTOM OF THE CABINETS.
IMPORTANT SAFETY INSTRUCTIONS
ALL RANGES
CAN TIP
INJURYTO PERSONS
COULD RESULT
INSTALL ANTI-TIP
DEVICE PACKED WITH
RANGE
SEE INSTALLATION
INSTRUCTIONS
If the information in this manual is not followed
exactly, a fire or electrical shock may result causing property
damage, personal injury or death.
Important Notes to the Installer
Read all instructions contained inthese installation instructions
before installing range.
Remove all packing material from the oven compartments
before connecting the gas & electrical supply to the range.
Observe all governing codes and ordinances.
Be sure to leave these instructions with the consumer.
EspaSol - Paginas 5-8
Important Note to the Consumer
Keep these instructions with yourowner's guide for future reference.
As when using any appliance generating heat, there are
certain safety precautions you should follow. These are listed
in the Use & Care Guide, read it carefully.
Be sure your range is installed and grounded properly by a
qualified installer or service technician.
Make sure the wall coverings around the range can withstand
the heat generated by the range.
To eliminate the need to reach over the surface elements,
cabinet storage space above the elements should be avoided.
Serial Plate Locations:
Serial
Serial plate is located on the lower right front frame of the appliance.
Alternate location may be under cooktop.
pin 316454912 rev A

Other manuals for Kenmore 9746 - 30 in. Electric Range

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kenmore 9746 - 30 in. Electric Range and is the answer not in the manual?

Kenmore 9746 - 30 in. Electric Range Specifications

General IconGeneral
BrandKenmore
Model9746 - 30 in. Electric Range
CategoryRanges
LanguageEnglish

Related product manuals