INSTALLATION AND SERVICE MUST BE PERFORMED BYA QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Clearances and Dimensions
1. Provide adequate clearances between the range and adjacent combustible surfaces.
2. Location--Check location where the range will be installed. Check for proper electrical supply, and the stability
of the floor.
3. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must
be solid and level.
F.ON 30÷
..................
Minimum to
wall on either 1"41 to
side of range
above 36" height.
/ iiiiiiiii
_ ®®)18 eitherside
I /
of range.
SIDE
VIEW
I_13"_'1
Maximum depth r-
for cabinets [F
above range top.
Fig. 1 _ 30-1/8" _ 0'clearancebelowcooldngl_pandatrearofrange.
RANGE
OVERALL
DIMENSIONS
with door handle T
Fig. 2
253/4'*
445_"
DoorOpen ,,'_"_
\ 29 7/8 _- _-
Centerline
of range
I
.i i
2-5/8" for models equipped
with warmer drawers"
3-1/2" for models equipped
with storage drawers
Fig. 3
Wall
Edge
*30"MiNiMUM CLEARANCE BETWEEN THETOP OFTHE COOKING SURFACEANDTHE BOTTOM OF AN UNPROTECTED
WOOD OR METAL CABINET; OR 24" MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET iS PROTECTED BY NOT
LESS THAN 1/4" FLAM ERETARDANT MILLBOARD COVERED WITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015"
STAINLESS STEEL, 0.024" ALUMINUM OR 0.020" COPPER. 0" CLEARANCE ISTHE MINIMUM FOR THE REAR OF THE
RANGE. FOLLOWALL DIMENSION REQUIREMENTS PROVIDEDABOVETO PREVENT PROPERTY DAMAGE, POTENTIAL
FIRE HAZARD, AND INCORRECT COUNTERTOP AND CABINET CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE
SPACE LOCATED ABOVE THE SURFACE UNITS SHOULD BEAVOIDED. IF CABINET STORAGE IS TO BE PROVIDED,
TH E RISK CAN BE REDUCED BY INSTALLING A RANGE HOOD THAT PROJ ECTS HORIZONTALLY A MINIMU M OF 5"
BEYOND THE BOTTOM OF THE CABINETS.
PIN 316259206 (1103) EN 1 EspaSoI-P_ginas7-12
Question and Answer IconNeed help?

Do you have a question about the Kenmore 30" ELECTRIC RANGE and is the answer not in the manual?

Kenmore 30" ELECTRIC RANGE Specifications

General IconGeneral
BrandKenmore
Number of Burners4
Self-CleaningYes
ColorStainless Steel
Width30 inches
TypeElectric

Summary

Clearances and Dimensions

Important Safety Instructions

Warning: Range Tipping Risk

Alerts that ranges can tip, causing injury. Emphasizes installing the anti-tip device.

Notes for Installer

Instructions for installers, including reading all manual sections and observing codes.

Note for Consumer

Advice for consumers on keeping instructions and ensuring proper installation and maintenance.

Normal Installation Steps

Anti-Tip Bracket Installation

Detailed instructions for installing the anti-tip bracket to secure the range, including locating and fastening.

Tools and Materials Needed

Lists tools required for leveling legs and anti-tip bracket, and materials for electrical connections.

Electrical Connection Requirements

Power Supply Cord Kits

Guidance on using approved power supply cord kits, conductor requirements, and terminals.

Electrical Connection to Range

Procedure for accessing the terminal block by removing the rear access cover.

Receptacle Types

Information on 3-wire and 4-wire electrical wall receptacle types and their installation requirements.

Range Connection Opening Size Chart

Chart correlating supply cord kit ampere rating with required range connection opening diameter.

Power Cord Connections

4-Wire Connection Instructions

Steps for connecting a 4-wire power cord, including disconnecting the ground strap and grounding the appliance.

3-Wire Connection Instructions

Steps for connecting a 3-wire power cord for existing installations, including grounding strap information.

Permanent Wire Connections

3 & 4-Wire Permanent Connections

Instructions for permanent wiring, covering both 3-wire and 4-wire setups, including grounding.

Slide Range into Final Location

Guidance on carefully moving the range into its final position, ensuring clearances and anti-tip engagement.

Related product manuals