KERN DS 8K0.05 Specifications

General IconGeneral
Capacity8 kg
Readability0.05 g
CalibrationExternal calibration
DisplayLCD
Reproducibility0.05 g
Power Supply230 V AC

Summary

1 Technical Data

2 Declaration of Conformity

3 Appliance Overview

3.1 Components

Identification of physical parts and features of the balance.

3.2 Operating Elements

3.2.1 Keyboard Overview

Details on the function of each button on the balance's keypad.

3.2.2 Numerical Input

Explanation of how to enter numerical values using the balance controls.

3.2.3 Overview of Displays

Interpretation of the symbols and information shown on the balance display.

4 Basic Information (General)

4.1 Proper Use

Instructions on intended use and correct operation of the balance.

4.2 Improper Use

Warnings and examples of incorrect or unsafe ways to use the balance.

4.3 Warranty

Conditions under which warranty claims may be voided.

4.4 Monitoring of Test Resources

Procedures for regular calibration and verification of balance performance.

5 Basic Safety Precautions

5.1 Read Operation Manual

Emphasizes the importance of reading the manual before use.

5.1 Personnel Training

Requirement for trained staff to operate and maintain the appliance.

6 Transport and Storage

6.1 Testing Upon Acceptance

Procedure for checking the balance for damage upon delivery.

6.1 Packaging Return Transport

Instructions for proper packaging and shipping of the balance.

7 Unpacking, Installation and Commissioning

7.1 Installation Site, Location of Use

Recommendations for choosing an optimal and safe installation environment.

7.2 Unpacking and Checking

Process for removing the balance from packaging and verifying its contents.

7.3 Assembling, Installation and Levelling

Steps for setting up the balance, including ensuring it is level.

7.4 Mains Connection

Instructions for connecting the balance to the power supply.

7.5 Rechargeable Battery Operation (Factory Option)

Details on using the optional battery for portable operation.

7.6 Connection of Peripheral Devices

Guidance on connecting external devices like printers or PCs.

7.7 Initial Commissioning

Steps to perform before the first use to ensure accurate operation.

7.8 Adjustment

7.8.1 External Adjustment

Process for calibrating the balance using a known external weight.

7.8.2 External Adjustment with User-Defined Adjustment Weight

Calibrating using a user-specified weight.

7.8.3 Gravitational Constant Adjustment Location

Setting the balance for local gravity variations.

7.8.4 Gravitational Constant Place of Location

Adjusting for geographical variations in gravity.

8 Basic Operation

8.1 Turn OnOff

Instructions for powering the balance up and down.

8.2 Simple Weighing

Basic steps for performing a standard weighing operation.

8.3 Zeroing

How to reset the balance to zero before weighing.

8.4 Taring

Procedure for subtracting the weight of a container.

8.5 Change-Over Button (Standard Settings)

Explanation of the multi-function button's default operations.

8.6 Underfloor Weighing

Method for weighing large or irregularly shaped items using a lower platform.

9 Operating Concept

Selecting an Application

Guide to choosing the correct operating mode (e.g., weighing, counting).

Change Application

Procedure for switching between different operational modes.

10 Application Weighing

10.1 Application-Specific Settings

Configuration options relevant to the weighing application.

10.2 PRE-Tare

Function for setting a pre-defined tare value.

10.3 Data-Hold Function

Feature to freeze the displayed weight value.

10.4 Weighing Units

Options for selecting and configuring measurement units.

11 Application Counting

11.1 Application-Specific Settings

Configuration options relevant to the counting application.

11.2 Piece Counting

Process for counting items based on average piece weight.

11.2.2 Target Counting

Function for counting items within predefined quantity limits.

12 Application Checkweighing

12.1 Application-Specific Settings

Configuration options relevant to the checkweighing application.

12.2 Target Weighing

Setting a target weight and checking if items meet it.

12.2.2 Checkweighing

Verifying if the weight of an item falls within specified limits.

13 Menu Navigation

13.1 Navigation in the Menu

General steps for moving through menu options.

13.2 Application Menu

Accessing specific application settings and modes.

13.3 Setup Menu

13.3.1 Overview Setup

Summary of all available setup options and their parameters.

14 Peripheral Communication

14.1 KERN Communications Protocol (KERN Interface Protocol)

Description of the protocol used for data exchange.

14.2 Issue Functions

Features related to data output and printing.

14.3 Data Format

Options for structuring the data transmitted from the balance.

15 Servicing, Maintenance, and Disposal

15.1 Cleaning

Instructions on how to clean the balance safely and effectively.

15.2 Servicing, Maintenance

Procedures for professional maintenance and repair.

15.3 Disposal

Guidelines for environmentally sound disposal of the balance.

16 Troubleshooting and Error Messages

16 Instant Help for Troubleshooting

Quick guide to common problems and their solutions.

17 Error Messages

Explanation of error codes displayed by the balance.