HIGHLANDER WOOD–FIRED BOILER – INSTRUCTION MANUAL
HIGHLANDER 15 Nov-09
2.10 INSTALLERS FINAL CHECKLIST
PIPING INSPECTION
1) Boiler plumbed properly?
2) Is a 12” x 36” expansion tank or equivalent installed?
3) Normally open by-pass zone valve installed?
4) Does the normally open zone valve by-pass to the main living area loop?
5) Is the normally open zone valve on the most direct piping loop (fewest elbows)?
BOILER INSPECTION
1) Are clearances maintained?
2) Are all firebricks in place in the boiler?
3) Is the relief valve piped back into the combustion chamber?
4) Is the system full of water and air eliminated?
5) Are zone valves and piping located to prevented drips on controls?
WIRING INSPECTION
1) Is main disconnecting switch within view?
2) Wiring cables protected from heat and not touching hot surfaces?
3) Check normally open zone valve (should heat gravity zone when valve open).
4) Check settings on all aquastats.
FLUE AND SMOKE PIPE INSPECTION
1) Flue inner size equivalent to 7” round or larger?
2) Separate entry to flue for both solid-fuel and oil or gas smoke pipes?
3) Smoke pipe 24 gauge or better?
4) Smoke pipe secured by screws?
5) Draft regulator (if used) set at .05” wc maximum?
6) Clearances of smoke pipe 18” or better from combustible material?
Metal protection is recommended.
2.11 PARALLEL PLUMBING WIRING EXPLANATION
a) The wood system neutral is connected to the oil boiler neutral.
b) The line power for the wood boiler must come from the same power disconnect switch as
the oil boiler.
c)
Single Aquastat (Honeywell L6006A1012)
Setting 160°F
This operates the circulation pump to circulate hot water between the two boilers when
the wood boiler is in operation.
d) Double Aquastat (Honeywell L6081A1010)
High Limit Left Side Setting 200°F
This is the wood high limit. If the water temperature in the wood boiler reaches 200°F the
wood boiler air damper is closed and the safety by-pass zone valve is opened. The end
switch on the safety by-pass zone valve makes a call for heat on the oil boiler triple
aquastat, which starts the primary circulator.