HIGHLANDER WOOD–FIRED BOILER – INSTRUCTION MANUAL
HIGHLANDER 2 Nov-09
SPECIFICATIONS
Cabinet Length 36”
Width 22”
Height 36”
Shipping Weight 600 lb.
Fire Box Length 36”
Width 16”
Height 26
Water Volume US Gallons 26.10
IMP. Gallons 21.73
Liters 98.80
Heat Exchanger 3/16” & 12-gauge steel
Fire Box Door Cast Iron 13” x 13”
Supply 1 1/4”
Return 1 1/4”
Smoke Pipe 7” Inside Diameter
Smoke pipe exit Top
Output (max) 70,000 Btu/h
Fuel Wood 30” logs maximum
Boiler Water Volume 26.0 U.S. gal.
Domestic Hot Water Coil Optional
Electrical Rating: Volts 120, 15Amps
Expansion Tank Size (recommended) 12” Dia. X 36” min. size
NOTE – Keep this manual in a safe place for future reference. Follow manual carefully for the
correct way to install and operate this unit.
CAUTION – Do not fire this unit until operating instructions have been read and fully
understood.
INSTALL WOOD-FIRED BOILER ONLY ON A FLUE SYSTEM AND CHIMNEY THAT ARE IN
GOOD CONDITION.
SAVE THESE INSTRUCTIONS
Tested by: Warnock Hersey Professional Services Ltd. to CSA standard B366.1
Certified by the Canadian Standards Association (CSA) May 1984
COSP. WWP-009
Manufactured by: Parrsboro Metal Fabricators Limited
12118 Hwy. 209, PO Box 637
Parrsboro, Nova Scotia B0M 1S0
Canada