1. Refer to Frame 45.
2. Drain down the boiler. Refer to Frame 60.
3. Unplug the electrical lead.
4. Unscrew the thermistor (to facilitate removal a
13mm socket spanner should be used).
5. Fit the new thermistor using the sealing washer
provided.
6. Reassemble in the reverse order.
7. Rell the boiler. Refer to Frame 22.
8. Check the operation of the boiler. Refer to Frame
36.
71
NO FLOW THERMISTOR REPLACEMENT
4
3
70
DHW FLOW REGULATOR CLEANING / REPLACEMENT
1. Refer to Frame 45.
2. Isolate the mains cold water supply to the
boiler.
3. Drain the boiler DHW circuit. Refer to Frame
60.
4. Remove the DHW ow turbine cartridge.
Refer to Frame 69.
5. Unscrew the ow regulator housing.
6. Inspect the ow regulator for any blockage
and remove if necessary.
7. Reassemble in reverse order.
8. Rell the boiler. Refer to Frame 22.
9. Check Operation of the boiler. Refer to
Frame 36.
6
5
SERVICING
207895-2.indd 54 02/01/2013 09:38:48