PARAMETS DESCRIPTION DEFAULT MIN MAX UNIT
12
IN.D.
(active if FP.r. dierent
from 2)
0 = deactivated
1 = barrier open light ON/OFF
2 = barrier open light proportional
- Slow ashing with barrier opening
- Quick ashing with barrier closing
- Steady light if barrier open
- 2 ashes + pause with barrier stationary (position other
than closed)
3 = Electric lock
4 = Magnetic electric lock function with output active when
barrier is closed
0 0 4
13
se.r.
Service interval cycle threshold.
(0 = o)
50 0 200
x 10.000
cycles
14
se.f.
Enabling of continuous ashing indicating
service required with se.r. ≠ 0 (only active with barrier
closed).
0 = o
1 = on
1 0 1
15
ST.P.
High-speed motor start-up.
0 = on
1 = o
1 0 1
16
DE.F.
1 = Restore of factory settings for sliding barrier motor
ALT324KF
1 0 1
and hold it down). A countdown should now appear: 49,48...,1 down