4 Using the Solar Array Simulator
70 Series E4360 Users Guide
Step 5. Specify how you want the list to terminate. You can either return to the
settings in effect before the list started, or remain at the settings of the
last list curve (step).
Front Panel:
SCPI Command:
Select
Transient\List\Terminate.
Select Return to start settings,
or Stop at last settings. Press
Select.
To return to the pre-list settings:
LIST:TERM:LAST 0,(@1)
To remain at the last list settings:
LIST:TERM:LAST 1,(@1)
Step 6. If applicable, specify how many times you want the list to run. Sending
the INFinity parameter in the SCPI command makes the list repeat
indefinitely. The default list count is 1.
Front Panel:
SCPI Command:
Select Transient\List\Count.
Enter the number of list counts
and Press Select.
To program the list to run twice,
use
LIST:COUN 2,(@1)
Select the Trigger Source
NOTE
An immediate trigger command over the bus will generate an
immediate trigger regardless of the trigger source.
Unless you are using the TRIG:TRAN:IMM command to trigger the
output, select a trigger source from the following:
Bus
Selects GPIB device trigger, *TRG, or <GET> (Group Execute Trigger).
Pin<number>
Selects a pin on the external port connector as the trigger source.
<n> specifies the pin number. The selected pin must be configured
as a Trigger Input to be used as a trigger source (see Appendix B).
Transient
<channel>
Selects the output channel’s transient system as the trigger source.
<channel> specifies the channel.
Dwell
<channel>
Selects the output channel’s dwell timer as the trigger source.
<channel> specifies the channel.
Use the following commands to select a trigger source:
Front Panel:
SCPI Command:
Select
Transient\TrigSource
.
Then select a digital pin,
transient channel, dwell
channel, or bus.
To select bus as the trigger source:
TRIG:TRAN:SOUR BUS,(@1)
To select a channel’s dwell output:
TRIG:TRAN:SOUR DWEL<n>,(@1)
To select a pin as the trigger source:
TRIG:TRAN:SOUR PIN<n>,(@1)
To select a transient channel:
TRIG:TRAN:SOUR TRAN<n>,(@1)

Other manuals for Keysight Technologies E4360A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies E4360A and is the answer not in the manual?

Keysight Technologies E4360A Specifications

General IconGeneral
BrandKeysight Technologies
ModelE4360A
CategorySwitch
LanguageEnglish

Related product manuals