Signal Input Connections
The input terminals of IN-1, IN-2, RST and HOLD are internally connected with pull-up resistance, so
when the terminals are not wired (suspended), the input on IN is a high level state. When the RST and
HOLD terminals are not used and are suspended, the input logic of RST and HOLD should be
reversed, that is, the parameter value of RH-N is ON (see "7. Parameter specification").
* This instrument is equipped with a sensor of NPN type.
If the meter USES PNP sensor, please contact us for the customization
6 Panel display and button operation
In normal mode, the display window displays the measured value (current value), the maximum value
and the minimum value. When the value exceeds the display range, it displays HHHH (HH); when it
exceeds the display range, it displays LLLL (LL).
In setup mode, the display window is used to display parameter symbols, parameter values, etc.