This instruction sheet covers the installation of the following Kichler® Transformers: 12217
200 WATT DIGITAL TRANSFORMER Input: 120VAC 60Hz 2A max. Output: 12VAC/15VAC 200VA max.
Read these instructions carefully before installing this unit. Save all safety warnings and instructions for
future reference.
This device is only accepted for use as a component of a landscape lighting system where the suitability of
the combination shall be determined by National Electric Code or local authorities having jurisdiction.
WARNING: Risk of electric shock, use only with low voltage landscape xtures and accessories. DO not use
with swimming pool or spa lighting xtures. Do not submerge transformer.
• Caution: Use only with maximum 180 watt, 180VA lamp load and a minimum 60 watt lamp load as speci-
ed below in Finding Transformer Load.
• Do not connect two or more power supplies in parallel.
• Do not touch the product. It may get hot during normal use.
• Suitable for indoor or outdoor use.
WARNING: Risk of Fire. If installation involves running wiring through a building structure, special wiring
methods are needed. Consult a qualied electrician.
Transformer should be mounted close to power source. Extension cords should not be used with this unit.
WARNING: RISK OF ELECTRIC SHOCK. Install power unit 5 feet (1.525m) or more from any pool, spa, or
fountain.
(a) indoor within 10 feet (3.05m) of a pool, spa or fountain, or
(b) outdoor, connect power to unit to a receptacle protected by a GFCI.
WARNING: Risk of Electric Shock. When used outdoors, install only to a 115/120 volt hood covered Class-A
GFCI protected receptacle, marked Wet Location, that is weatherproof with the power unit connected to
the receptacle. If one is not provided, contact a qualied electrician for proper installation. Ensure that the
power unit and cord do not interfere with completely closing the receptacle cover.
• Mount the rain-tight transformer at least one 1ft (.305m) above ground level with the wire terminals facing
down. NOTE: Do not energize transformer until installation of system is complete.
• Direct burial rated wire is to be buried a maximum of 6” (152.4mm) beneath the surface of the ground.
• Risk of re. Do not place insulation under terminal plate. Check connection after installation.
1
Kichler® is a registered trademark of
The L.D. Kichler Co. All Rights Reserved.
MODEL #12217
Question and Answer IconNeed help?

Do you have a question about the Kichler Lighting Showscape 12217 and is the answer not in the manual?

Kichler Lighting Showscape 12217 Specifications

General IconGeneral
TypeTransformer
SeriesShowscape
Wattage300W
Input Voltage120V
Output Voltage12V
MaterialMetal
Weather ResistantYes
LocationOutdoor
Maximum Load Capacity300W
Number of Outputs1
Power Output300 Watts

Summary

Installation Instructions

Finding Transformer Load

Calculate required transformer wattage based on bulb types and quantities.

Transformer Mounting Location

Guidance on selecting an appropriate mounting location for the transformer.

Wall Mounting Transformer

Instructions for directly mounting the transformer onto a wall surface.

Surface Mounting Options

Steps for mounting to solid surfaces like wood or drywall.

Securing Transformer to Screws

Process for attaching the transformer using keyhole slots.

Final Transformer Tightening

Ensuring the transformer is securely fastened.

Cable Run Layout Planning

Strategies for planning and zoning cable runs for landscape lighting.

Wire Gauge and Voltage Tap Selection

Selecting wire gauge and voltage tap for optimal performance and voltage.

Low Voltage Cable Preparation

Steps for preparing the low voltage cable for connection.

Connecting Common Wire

Connecting the common wire to the transformer terminal block.

Connecting Voltage Taps

Connecting remaining wires to the transformer voltage taps.

Landscape Lighting Warranty and Limitations

Operation

Setting the Clock to Local Time

Steps to set the local time on the transformer's digital display.

Timer ON/OFF Control

How to set the transformer to turn lights on/off via a timer.

Photo Eye Auto ON/OFF Control

Setting the transformer to use the photo eye for dusk-to-dawn operation.

Photo Eye ON / Time OFF Control

Setting the transformer to use photo eye for ON and manual for OFF time.

Manual ON/OFF Override

Bypassing programming modes to manually turn lights on and off.

Photo Eye Test Function

Testing landscape lighting operation after installation and programming.