ARIES
®
-MLX, ARIES
®
-SLX
LED and Relay Output Driver Modules
Models ATM-L and ATM-R
FEATURES
Model ATM-L supports 32 programmable, supervised
LED outputs, 6 system-level LED outputs and 5 system-
level input circuits
Model ATM-L supports 32 programmable LED outputs, 6
system LED outputs and 5 system inputs
Model ATM-R activates up to 32 programmable relays
Up to 16 ATM-L, ATM-R or combination of both per
control unit
Can be mixed with up to 15 RDCMs per control unit
Can be installed up to 4000 feet (1219 meters) from
control unit
Supports applications with legacy Kidde Fire Sys-
tems control units
UL Listed and FM Approved
DESCRIPTION
The Model ATM-L Annunciator (LED) Driver Module (P/N
76-200004-032) provides ARIES
®
-MLX, ARIES
®
-SLX or
legacy control units (ARIES
®
NETLink, ARIES
®
) with up
to 32 programmable, supervised LED outputs for graphi-
cal or tabular annunciators, along with 6 system-level
LED outputs and 5 system-level input circuits for func-
tional switches.
The system-level LEDs correspond to the following gen-
eral conditions:
Module Power
•Alarm
Pre-Alarm
Alarm Silence
Supervisory
Trouble
The functional switches provide for the following operator
intervention:
System Reset
Event Acknowledgment
Alarm Silence
Fire Drill
•Lamp Test
The Model ATM-R Relay Driver Module, P/N 76-200005-
032, can activate up to 32 programmable, supervised
relays.
These modules communicate with the control unit via an
external RS-485 communications circuit, with the most-
remote module capable of being located up to 4,000 feet
from the control unit. Up to 16 remote ATM-L, ATM-R or
combination of both can be mixed with up to 15 RDCMs
on the control unit's RS-485 circuit.
Both modules can be powered from the control unit’s
power supply, or from an external, regulated, and power-
limited power supply Listed for use with fire-protective-
signaling equipment.
Model ATM-L Annunciator Driver Module
INSTALLATION
The ATM-L Module is intended for mounting inside the
enclosure of a UL-864 Listed remote annunciator. Use
the mounting hardware provided with the module. Wire
routing and installation methods are to be in accordance
with the annunciator installation instructions.
The ATM-R is intended for mounting inside the enclosure
of a UL-864 Listed accessories cabinet. Use the mount-
ing hardware provided with the module (see Figure 1).
Figure 1. Module Mounting Dimensions
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Lamp Test
Com
Ack
Reset
Silence
Drill
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
LK19
LK21
LK18
LK20
LK23
LK22
LK25 LK24
LK27 LK26
LK29 LK28
LK31 LK 30
LK32
LK17
LK15LK16
LK13LK14
LK11LK12
LK10
LK8
LK6
LK4
LK2
LK9
LK7
LK5
LK3
LK1
Trouble
Sup.
Sil. Out
Pre Alm
Alarm
Pwr On
A
B
+24 V
Com
PS Flt
W1
Out B
Out A
In B
In A
S2 S1
ATM-L/R
Earth Gnd
1.375 5.175
0.188
4.625
8.000
5.000
Note:
Maintain a minumum one-half (1/2) inch clearance around ATM-L
and ATM-R Modules when installed in mounting enclosure.
Effective: May 2020
K-76-236