Power: Three AA batteries (supplied)
Sensor: Electrochemical carbon monoxide
sensor
Humidity: 5-95% Non condensing
Temperature: Operating range 40°F (4.4°C) to
100°F (37.8°C)
Mounting: Accessories supplied for wall mounting
Alarm: 85+ dB at 3m @ 3.4 ± 0.5 KHz
pulsing alarm
LED Operation: • Flashing green LED every 30 seconds
indicates proper operation
• Red LED with loud 85db alarm
indicates presence of CO
Battery
Replacement: Red and green LED flashes, and the
unit chirps every 30 seconds. Replace
the three AA batteries with one of the
following brands.
• Duracell MN1500
• Energizer E91
• Rayovac 815
Unit Malfunction: Red light flashes, and the unit chirps
every 30 seconds indicates a unit error.
Refer to page 7.
Test/Reset Button: Test button verifies proper unit