2. Product Features and Specifications
Green,
Power LED
Red,
Alarm LED
Test / Reset
Button
Peak Level Button
Digital Display
Green,
Power LED
Red,
Alarm LED
Test / Reset
Button
WARNING: After ten (10) years from initial power up, this
alarm will “beep” two times every 30 seconds to indicate that it
is time to replace the alarm. Replace the alarm immediately! It
will not detect CO in this condition.
End of Life Notification
End of Life “Hush”: This model has an End of Life Hush feature which
allows you to press the test/reset button on the alarm and disable the
“chirps” for a period of 3 days. This gives you a chance to replace the
alarm at a more convenient time while still providing protection. The
two chirps will repeat again every 3 days and can be reset a total of 30
days. After 30 days, the End of Life signal cannot be “Hushed.” The
alarm must be replaced.
During this End of Life HUSH period, your alarm is monitoring for CO.
To help identify the date to replace the alarm, a label has been affixed
to the side of the alarm. Write the “replace by” date (ten years from
power up) in a permanent marker on this label.
Model KN-COB-LP2
!
Temperature:
Operating Range: 40°F (4.4°C) to 100°F (37.8°C)
Humidity:
Operating range: 10-95% non-condensing
Audible Alarm:
85+ dB at 10’ @ 3.4±0.5 KHz pulsing alarm
Sensor:
Electrochemical
Power:
2-AA Batteries
Alarm Response Times:
70 PPM = 60-240 min., 150 PPM = 10-50 min., 400 PPM = 4-15 min.