Because carbon monoxide is a cumulative poison, long-term expo-
sures to low levels may cause symptoms, as well as short-term
exposures to high levels. This Kidde unit has a time-weighted
alarm - the higher the level of carbon monoxide present, the sooner
the alarm will be triggered.
This CO alarm can only warn you of the presence of CO. It does
not prevent CO from occurring, nor can it solve an existing CO
problem. If your unit has alarmed and you’ve provided ventila-
tion by leaving your windows and doors open, the CO buildup
may have dissipated by the time help responds. Although your
problem may appear to be temporarily solved, it’s crucial that the
source of the CO is determined and that the appropriate repairs
are made.
What To Do If The Alarm Sounds (continued)
This CO alarm meets the alarm response time requirements as follows:
At 70 PPM, the unit must alarm within 60-240 minutes
At 150 PPM, the unit must alarm within 10-50 minutes
At 400 PPM, the unit must alarm within 4-15 minutes
WARNING
This product is intended for use in ordinary indoor residential
areas. It is not designed to measure compliance with commercial
and industrial standards.
This device is designed to protect individuals from acute effects
of of carbon monoxide exposure. It may not fully safeguard indi-
viduals with specific medical conditions. If in doubt, consult a
medical practitioner. Individuals with medical problems may con-
sider using warning devices, which provide audible and visual sig-
nals for carbon monoxide concentrations under 30 ppm.
20