Install smoke alarms on sloped, peaked or cathedral
ceilings at or within 0.9 m (3') of the highest point
(measured horizontally). NFPA Standard 72 states:
“Smoke alarms in rooms with ceiling slopes greater than
0.3 m in 2.4 m (1 foot in 8 feet) horizontally shall be
located on the high side of the room.” NFPA Standard
72 states: “A row of detectors shall be spaced and
located within 0.9 m (3') of the peak of the ceiling
measured horizontally” (Image 2B).
4
Installation
D
INING
ROOM
LIVING
ROOM
Smoke Alarms for Minimum Protection
Ionization Type Smoke Alarm with
Hush® Control or Photoelectric Type
Smoke Alarms for Additional Protection
K
ITCHEN BEDROOM
BEDROOM
B
EDROOM
LIVING
ROOM
KITCHEN
BEDROOMBEDROOM HALL
B
ASEMENT
IMAGE 1A
IMAGE 1C
IMAGE 1B
SINGLE FLOOR PLAN MULTIPLE FLOOR PLAN
BEDROOM
FAMILY ROOM
WORKSHOPBASEMENT
KITCHEN
HALL
GARAGE
MASTER
BEDROOM
FIRE
EXTINGUISHERS
SMOKE
ALARMS
CARBON
MONOXIDE
ALARMS
TALKING
SMOKE/CO
ALARM
TOTAL HOME PROTECTION