  • G
    gonzalezphillipAug 9, 2025
    Why is the ALARM activated on my Kikusui Measuring Instruments?
    • J
      Joshua CooperAug 9, 2025
      The ALARM may activate on your Kikusui Measuring Instruments due to: * Overheat protection tripped. In this case, immediately stop using the instrument and request repairs. * Overheat protection tripped because of a clogged dust filter. Ensure there is at least 20 cm of space between the air outlet and any wall, and keep objects at least 20 cm away. Clean the dust filter. * The OCP or OPP setting is too small. Reset the OCP or OPP value in the setup screen.
  • J
    Jeremy StoutAug 14, 2025
    Why is the input current unstable or oscillating on my Kikusui Measuring Instruments?
    • L
      Lisa FreemanAug 14, 2025
      Unstable or oscillating input current on your Kikusui PLZ-4WH Measuring Instruments can be caused by: * Low supply voltage. Use the PLZ-4WH within the correct input supply voltage range. * An internal or external error. Check the alarm type and apply the appropriate fix. Other solutions include twisting the wires and changing the response (transient response) using the menu setup. If the issue persists, immediately stop using the instrument and request repairs.
  • K
    Kari WhitakerAug 19, 2025
    How to fix a Kikusui Measuring Instruments when nothing appears on the display?
    • E
      Elizabeth DanielsAug 19, 2025
      If nothing appears on the display of your Kikusui Measuring Instruments when you turn on the power, check the following: * Ensure the power cord is not broken and is securely connected to the AC INPUT connector on the rear panel. If this doesn't resolve the issue, remove the power cord plug from the outlet, immediately stop using the instrument, and request repairs.
  • L
    Lindsay BrownAug 25, 2025
    What to do if the keys do not work on Kikusui Measuring Instruments?
    • S
      Samantha MerrittAug 25, 2025
      If the keys on your Kikusui Measuring Instruments are not working, it could be because the key lock is enabled. Release the key lock. If this doesn't solve the problem, immediately stop using the instrument and request repairs.
  • M
    Mr. Andrew SilvaAug 29, 2025
    Why the load cannot be turned on on my Kikusui Measuring Instruments?
    • L
      Lisa DavisAug 29, 2025
      The load on your Kikusui Measuring Instruments might not turn on because: * The sequence operation is in progress. Wait for it to finish or abort it by pressing STOP. * The load on/off logic (Load ON IN) is set to low. In the menu, select “Configuration” and set “Load ON INput” to “HIGH.”
  • N
    Nicholas MunozSep 3, 2025
    How to fix a dark display on Kikusui Measuring Instruments?
    • K
      Katie LopezSep 3, 2025
      A dark display on your Kikusui Measuring Instruments can be due to: * Low supply voltage. Use the PLZ-4WH within the specified input supply voltage range. * Incorrect contrast adjustment. Adjust the contrast.

Kikusui PLZ-4WH Series Specifications

General IconGeneral
TypeElectronic Load
DisplayLCD
Number of Channels1
SeriesPLZ-4WH
Maximum Input Current40 A
Communication InterfaceUSB, RS-232C, GPIB
Control ModesConstant Current (CC), Constant Voltage (CV), Constant Resistance (CR), Constant Power (CP)
Protection FunctionsOver Voltage Protection (OVP), Over Current Protection (OCP), Over Power Protection (OPP)

Related product manuals