Cooling Method | Forced Air Cooling |
---|---|
Series | PWR-01 |
Type | Programmable DC Power Supply |
Current Accuracy | 0.1 % + 2 mA |
Operating Temperature | 0°C to 40°C |
Storage Temperature | -20°C to 70°C |
Humidity | 20% to 80% RH (non-condensing) |
Input Frequency | 47Hz to 63Hz |
Protection Functions | Overvoltage, Overcurrent, Overtemperature |
Interface | USB, RS232 |
Remote Sensing | Yes |
CV/CC Priority | Available |
Weight | Approx. 5 kg |
Describes the manual's PDF format and viewing requirements.
Specifies the target audience and required prior knowledge.
Lists the sections included in the manual.
Lists registered trademarks used in the manual.
States the firmware version this manual applies to.
Lists standards the PWR-01 conforms to.
Explains the requirement and types of VISA libraries.
Covers physical connection and configuration for RS232C, USB, and LAN.
Details configuring multiple PWR-01 units for multichannel operation.
Explains password protection and accessing via web browser.
Explains SCPI command hierarchy, syntax, and structure.
Defines SCPI command format and notation.
Explains manual notation symbols and how to query device status.
Explains data types (numeric, string, boolean) for SCPI parameters.
Clears event registers, status byte, event status, and error queue.
Manages event status enable and event status registers.
Queries instrument identification and learning commands.
Manages operation complete bit and installed options.
Sets power-on status clear and resets panel settings.
Manages service request enable register and status byte.
Trigger command, self-test execution, and wait command.
Aborts operations like change and sequence execution.
Aborts the sequence trigger function.
Aborts the setting change trigger function.
Adjusts the screen brightness.
Resets panel settings for all channels in a multichannel domain.
Triggers all channels and aborts multichannel operations.
Sets current for all channels and starts sequence trigger.
Starts transient trigger and controls output for all channels.
Clears alarms and sets voltage for all channels.
Starts the sequence trigger function.
Starts the setting change (TRANsient) trigger function.
Specifies channel and queries list of configurable channels.
Queries information about the currently controlled channel.
Queries the current and voltage for specified or default channel.
Queries the measured value of the current.
Queries the measured value of the voltage.
Recalls voltage, current, OVP, UVL, OCP from preset memory.
Queries settings stored in preset memory.
Saves current voltage, current, OVP, UVL, OCP to preset memory.
Turns the output on and off.
Sets output-on and output-off delay times.
Controls external output and advance settings.
Sets logic for external control and output state at power-on.
Clears alarms and sets communication monitor timer.
Sets whether to output a trigger signal when output is turned on.
Deletes existing program and creates a new one.
Changes the number of times a program will repeat.
Queries remaining loop count and time in a running sequence.
Queries program steps and sets interval loop parameters.
Sets current and transition for program steps or template.
Sets execution time for program steps or template.
Sets trigger signal input for program steps or template.
Sets trigger signal output for program steps or template.
Sets voltage and transition for program steps or template.
Sets the user code to identify sequences.
Sets the current level.
Sets CC/CV range and external current control source.
Enables or disables the limit on the current setting.
Sets the overcurrent protection (OCP) value.
Sets the detection time of OCP activation.
Sets the soft stop time when the output is turned off.
Sets soft start time and current value on trigger.
Sets the internal resistance.
Sets the voltage level.
Sets CC/CV range and external voltage control source.
Sets voltage limit to avoid OVP or UVP.
Sets the undervoltage limit (UVL) trip point.
Sets the overvoltage protection (OVP) value.
Sets the soft stop time when the output is turned off.
Sets soft start time and voltage value on trigger.
Explains the SCPI status register architecture and bit definitions.
Details the structure and bits of the status byte register.
Describes bits related to events like OPC, RQC, and errors.
Describes bits indicating normal operation states (SST, ODEL, PROG).
Commands to query and set the operation status register.
Commands to query and set the questionable status register.
Command to reset all status register filter settings to defaults.
Controls the instrument's buzzer on/off.
Sets the instrument to local or remote operation mode.
Various configuration settings for the system.
Commands to retrieve and manage error queue information.
Configures polarity for external status signals.
Configures polarity for external trigger signals.
Controls the panel operation lock (keylock).
Executes software triggers for program sequences.
Queries the state of program sequences.
Sets the trigger source for program sequences.
Executes software triggers for transient operations.
Sets the trigger source for transient operations.
Basic control of voltage, current, and protection functions.
Synchronizing output changes using triggers.
Creating and executing program sequences.
Procedures for checking and displaying instrument errors.
Sample code for controlling the device with Visual Basic.
Categorized list of command, execution, and device-specific errors.
Typical processing times for various commands across interfaces.